The HP ProLiant DL380p Gen9 (Generation 9) server performance model with enhanced configuration flexibility, high performance, and leading energy efficient design offers the perfect solution for demanding video applications.
Electrical | |
Input requirements (per 500 W power supply) | |
range line voltage | 100 to 120 VAC, 200 to 240 VAC |
rated input current | 5.8 A at 100 VAC |
2.8 A at 200 VAC | |
rated input frequency | 50 to 60 Hz |
rated input power | 580 W at 100 VAC max |
560 W at 200 VAC max | |
BTU rating | 1979 BTU/h at 100 VAC |
1965 BTU/h at 200 VAC | |
Output power (per power supply) | |
rated steady-state power | 500 W at 100 to 120 VAC |
500 W at 200 to 240 VAC | |
maximum peak power | 500 W at 100 to 120 VAC |
500 W at 200 to 240 VAC |
Mechanical | |
Dimensions (H x W x D) | 8.73 x 44.55 x 73.02 cm (3.44 x 17.54 x 28.75 in) |
Environmental | |
System inlet temperature | |
operating | 10 °C to 35 °C (50 °F to 95 °F) at sea level with an altitude derating of 1.0 °C per every 304.8 m (1.8 °F per every 1000 ft) above sea level to a maximum of 3048 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10 °C/h (18 °F/h). The upper limit may be limited by the type and number of options installed. |
System performance may be reduced if operating with a fan fault or above 30 °C (86 °F). | |
non-operating | -30 °C to 60 °C (-22 °F to 140 °F). Maximum rate of change is 20 °C/h (36 °F/h). |
Relative humidity | |
operating | 10 to 90% relative humidity (Rh), 28 °C (82.4 °F) maximum wet bulb temperature, non-condensing |
non-operating | 5 to 95% relative humidity (Rh), 38.7 °C (101.7 °F) maximum wet bulb temperature, non-condensing |
Emissions classification (EMC) | |
FCC rating | Class A |
normative standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 |